Key takeaways for CVE-2026-116779
- CVE-2026-116779 affects SignalWire FreeSWITCH versions through 1.11.2. SignalWire rated it Critical with a CVSS 3.1 score of 9.8, Bitsight’s threat intelligence report assigns it a DVE score of 10.0/10.
- A crafted inbound SIP MESSAGE can select FreeSWITCH’s
apichat protocol. This lets the server execute API commands with the privileges of the FreeSWITCH process, potentially opening the door to OS command execution, configuration and credential disclosure, and call manipulation. - SignalWire says exploitation has been observed in the wild. CISA added the vulnerability to its Known Exploited Vulnerabilities (KEV) catalog on November 9. Public proof-of-concept code has also appeared in public repositories.
- Inbound chat is enabled by default in the stock internal and external profiles. Where message authentication is required, an attacker needs access to a valid account on that profile. The stock vanilla directory also includes users without password material; depending on configuration, those users may allow access without separate credentials.
- The best fix is to upgrade to FreeSWITCH 1.11.3 or later. If patching takes time, set
enable-chat=falseon any profile that does not need inbound SIP chat. The FreeSWITCH inbound ACL and message authentication alone do not close the attack path.
What happened?
On October 28, SignalWire released an advisory about a flaw in how FreeSWITCH parses inbound SIP MESSAGE requests. Versions through 1.11.2 are affected, and version 1.11.3 includes the fix. SignalWire says exploitation has been observed in the wild, though it has not shared technical details about those attacks. CISA added CVE-2026-116779 to its Known Exploited Vulnerabilities catalog on November 9. This addition is a reason for organizations to prioritize patching, especially for servers reachable over public networks or supporting critical telephony services.
Proof-of-concept code has also appeared in public repositories. These repositories can lower the technical bar for potential attackers, but their presence alone does not establish that the code works or reflects the attacks SignalWire observed. The vendor has not commented on the reliability of those repositories.
How CVE-2026-116779 works
Under the hood, FreeSWITCH’s sofia_presence_handle_sip_i_message() function splits the user portion of the SIP MESSAGE “To” field at a plus sign, treating the left side as the name of a chat protocol. An attacker can craft an address that selects the api protocol. FreeSWITCH’s mod_dptools module registers that protocol and passes the selected API address to switch_api_execute(), which runs FreeSWITCH API commands. Because certain API commands can interact with the underlying operating system, successful exploitation can result in command execution with the privileges of the FreeSWITCH process.
This flaw lets inbound messages invoke FreeSWITCH API commands. SignalWire says an attacker could disclose configuration and credentials or manipulate calls. If mod_lua is loaded, as it is in the stock configuration, inline Lua scripts with access to the full standard library provide another route to command execution. The real-world impact depends on the permissions assigned to the FreeSWITCH service and its environment.